    Posted by paul m marshall on March 2, 2007, 10:34 pm, in reply to "Re: peugeot expert 2.0 hdi 2000 RHX bosch EDC15C2"

    hi andy

    i have had this in the past when the battery voltage drops below 9 volts when cranking causing a no start, the engine control module must see about 10 volts on crank, this could explain why it starts when towed.
    using the live data/pids you need to ensure the supply pump from tank is operating
    high pressure pump is creating more than 118bar and battery volts do not fall below 9 volts on crank.

    hth
    paul m marshall