Posted by David Davies on December 10, 2011, 4:46 pm, in reply to "Audi A4 Hard starting"
David Davies
The system should hold i.5 bar pressure and not drop.The test in Elsawin is to clamp off supply and return pipes from tank pump,then connect cooling system pressure tester to tandem pump test port(using appropriate adapters) and apply 1.5 bar test pressure.