Stoneridge Engineering Home |
Posted by Bert Hickman Mario, The primary (220 volt) side of the arc welder is connected in series with the LV winding of the distribution transformer. The LV secondary of the welder is then short-circuited, and the welder current setting adjusted for the desired output power level. Be very careful - you are working with instant death here! Best regards, -- Bert --
![]()
on 9/4/2003, 12:31 am, in reply to "Pole Pig"
12.250.78.105
--Previous Message--
: I have a 10kva transformer and would like to make a jacobs ladder just to
: make sure it works alright. Can someone tell me the proper way to wire
: it using a arc welder as the ballast. I am fairly sure that just one of
: the wires run through the welder. I just want to be certain as this
: thing is rather dangerous. Thanks Mario marioseek29@juno.com