Posted by GA on April 8, 2004, 9:53:32, in reply to "Direct serial connection H8S2633" The H8S device is not entering boot mode correctly. To put the device into boot mode the mode pins should be set as below. MD1 = 0 The FWE pin should be high and the device reset. If after checking these settings it still doesn't work make sure that Rx on the H8S is connected (via an RS232 level shifter) to Tx on the PC and Tx on the H8S is connected (via an RS232 level shifter) to Rx on the PC. GA --Previous Message--
194.131.190.1
Hi,
MD2 = 0
: I am using a prototype of my board with
: FDK3.1 with direct serial connection
: and am not able to connect, get the
: following message
: Connecting to device 'H8S/2633F' on
: 'COM1'
: Configuration: 'BOOT Mode' connection
: - using emulated interface
: Opening port 'COM1' ...
: Loading Comms DLL
: Loaded Comms DLL
: Initiating BOOT SCI sequence
: Attempting 9600
: Attempting 4800
: Attempting 2400
: Attempting 1200
: Error No 15024: Boot failed
: Unloaded Comms DLL
: I am using RX, TX and GND pins only.
: Any suggestions?
: I am pulling reset low,
: then pulling MD2 low and FWE high
: manually and taking reset high and
: starting the flash sequence with no
: result
: I can see RX trying to autoadjust
: going into RX pin SCI2 channel. There
: is no response on TX pin SCI2 channel
: .
:
:
Message Thread:
![]()