Posted by DrE on September 25, 2003, 9:46:28, in reply to "H8/3062BF and FDT" In addition, when you create the FDT2.2 workspace, ensure that the specified XTAL frequency matches that of your device. The FDT2.2 default XTAL is 25MHz. If using FDT in direct connect mode ( This is the best way to use FDT ) ensure that the device is in boot mode!! Sounds obvious, but many people don't do this. Hope this helps. --Previous Message--
194.131.190.5
Roger,
The 3062BF is a B mask (0.35um) device. As such, use the protocol B.
Protocol A is for 0.6um devices and there is a fundemental difference between the FLASH 0.35 & 0.6 um technology.
This could be why you are having problems.
: Does anyone have any experience using
: FDT to program the H8/3062BF device.
: I'm working on a project and I'm
: trying to use FDT2.2 to program a
: 3062BF device. I'm not sure what I'm
: doing wrong, but FDT 2.2 refuses to
: connect. It gives a read timeout
: error when it tries to reset the
: interface. I am using protocol A,
: with a baud rate of 38400bps.
: Does anyone have any idea where I
: could be going wrong? Any advice
: would be welcome.
: Thanks,
: Roger Harper
: