Posted by herb on 2/2/2007, 11:48 am, in reply to "Need Falcon mechanic (electrical) SE Wisconsin" --Previous Message--
69.168.141.131
Hey Dan, have you tried polarizing the generator ? With engine off disconnect the field wire and the battery wire at the voltage regulator and touch them together momentarily. Hope this does it.
Herb
: I've had it. I have two rebuilt
: generators that are both supposedly
: working. I have two new voltage
: regulators. I have checked the wires
: that go from the voltage regulator
: to the generator and they are good.
: I have recleaned and recleaned the
: grounds--and the @#$%^%#$%^&
: won't generate. I am now willing to
: swallow my pride and pay someone to
: fix this by spring. This is a 1960
: Ranchero with a 1966 200 six, if
: that makes a difference. As always,
: thanks for the help.
:
Message Thread:
![]()
« Back to thread